What Are IPMI and BMC? Remote Management with iLO and iDRAC

What Are IPMI and BMC? Remote Management of a Dedicated Server with iLO, iDRAC and ILOM

What Are IPMI and BMC? Remote Management of a Dedicated Server with iLO, iDRAC and ILOM

When the operating system of a dedicated server does not boot, when a network setting breaks or when the server suddenly shuts down, the only way left is often the management controller called IPMI/BMC. This controller works like a separate small computer on the motherboard: even while the server is off it can power it on or off, read temperatures and fan speeds and record hardware events. In this guide we explain what IPMI and BMC are, how iLO, iDRAC and ILOM differ, what can be done from the panel of your dedicated server, why a hard reset is risky and how the hardware event log is used in a shutdown inspection.

What are BMC and IPMI?

A BMC (Baseboard Management Controller) is a management controller on the motherboard that works independently of the operating system. It has its own processor, its own memory and, most of the time, its own network connection; as long as power is supplied to the server it runs, even if the operating system has never started. IPMI (Intelligent Platform Management Interface) is the standard protocol used to talk to the BMC. In short, the BMC is a piece of hardware and IPMI is the language used to talk to it.

Being independent of the operating system is the biggest advantage of the BMC. Even if the operating system has crashed, a disk is corrupted or SSH cannot be reached because of a network setting, you can see the server's screen, manage its power and read the state of the hardware through the BMC.

iLO, iDRAC and ILOM: the same idea, different brands

Each vendor offers its BMC under its own name. The three names you meet when choosing a dedicated server are:

NameVendorGeneral feature
iLOHPEConsole in the browser, power actions, sensors and event log
iDRACDellConsole in the browser, power actions, sensors and event log
ILOMOracle / SunPower, sensors and event log over IPMI; the console is Java-based and is not offered from the panel
Generic IPMI/BMCVarious motherboard makersVaries by maker: console, power and sensors

All these controllers do the same basic jobs; the differences appear in the interface, the console technology and the supported protocols. Newer iLO and iDRAC versions offer a modern web interface and a programmable interface called Redfish; older controllers support only IPMI or a Java-based console.

What can you do with a BMC?

  • Power actions: power on, shut down, restart and hard reset. When the server is off, this is often the only way to power it on.
  • Console (KVM): use the server's screen and keyboard remotely. You also see the BIOS screen before the operating system starts.
  • Sensors: CPU and memory temperature, fan speed, power supply state. You can see in advance when a temperature threshold is crossed.
  • Hardware event log (SEL): a persistent record of events such as power loss, overheating and fan or power supply failure.
  • Next boot selection: send the next boot to BIOS, PXE, virtual CD, disk or USB. The selection applies only once.
  • Virtual media: attach an ISO file remotely to the server like a CD and install an operating system. This feature varies by hardware.
  • BMC reset: restart only the BMC itself when it hangs; it does not affect the running server.

What can be done from the panel on SistemDC dedicated servers?

On SistemDC dedicated servers, remote management is included in the plan price and is used from the client panel. On Intel Xeon servers an HTML5 console opens in the browser through iLO (HPE) or iDRAC (Dell); on older hardware a Java console may be needed. On servers with IPMI, the panel shows power actions (power on, restart, power off, hard reset), hardware sensors (CPU and memory temperature, fan speed), system logs, the "Next Boot" card (BIOS, PXE, virtual CD, disk, USB, UEFI Shell; applied once), BMC reset and hardware details. On Oracle / Sun ILOM servers, power actions, sensors, the hardware event log and next boot are managed from the panel; however the console is Java-based and is not offered from the panel, and a support request is opened when needed. You can find what each server has in the remote management and KVM document.

A dedicated server with remote management included

Reach your server with IPMI/BMC even when the operating system does not boot.

See the dedicated servers

Why is a hard reset risky?

In the panel, "Restart" and "Hard Reset" both start the server again but they are not the same. A hard reset resets at hardware level without giving the operating system a chance to shut down; it is like pressing the reset button of a running computer. Open files, database operations being written and data in cache can be left half-finished, and the file system can be corrupted. On some motherboards even "Restart" from the panel can reset at hardware level without sending a proper shutdown signal to the operating system; so before restarting an important server, the safest route is to stop services and restart from inside the operating system.

This is why the agreement also states that power actions taken over the BMC are carried out on the customer's instruction, and that data loss or file-system corruption that may result from a hard reset or forced power-off is the customer's responsibility. The rule is simple: try a shutdown from the operating system first, and use a hard reset only on a server that does not respond.

Reading the hardware event log (SEL)

The hardware event log is one of the strongest sources for understanding why a server suddenly stopped, because the BMC records the event before the operating system can even notice it. In the log you typically see:

  • Power supply events: a power supply losing its AC input, a backup supply taking over or failing.
  • Temperature events: a sensor crossing its upper threshold, followed by a shutdown.
  • Fan events: fan speed dropping or a fan stopping.
  • Memory and CPU events: an uncorrectable memory error, a processor error.
  • Boot progress records: noisy lines written during POST; moving them to the end makes reading easier.

Watch for two traps when reading the log. The first is the time offset: the BMC's clock can differ from the operating system's clock, so account for the shift when comparing event times. The second is old leftovers: if the log is full and has not been cleared, records from years ago can be confused with today's problem; look at the date of the record. We explained how to solve a shutdown from the records in the why did my server shut down guide.

How to interpret sensor values

On the sensor screen, look not only at the number but at its distance from the threshold. A CPU temperature of 70 degrees may be normal; what matters is the warning and critical thresholds the vendor defines. A sudden drop in fan speed is a sign of dust build-up or a fan failure. If there are two power supplies, both should see AC input; if only one sees input, the server keeps running but redundancy is lost. This appears as a warning in the panel and it is correct; the solution is to plug in the backup cable, not to silence the sensor.

BMC security: why it should not be open to the internet

Because the BMC can reach the server's hardware from beneath the operating system, it is a powerful management path and therefore also a target for attackers. Basic rules for security:

  • Do not open the BMC directly to the public internet; reach it from a management network or through a path bridged via the panel.
  • Change the default username and password; use a strong, unique password.
  • Turn off unnecessary protocols and users; keep the firmware version up to date.
  • Watch access records; if you see a session you do not recognize, change the password immediately.

On SistemDC dedicated servers BMC access is offered bridged through the panel, so the controller interface is not itself opened to the internet.

What to do if the console does not open

When the console does not open, try these in order: use a different browser or a private window; make sure a corporate firewall or VPN does not block the connection; regenerate the console link in the panel; if it still does not open, try a BMC reset (it does not affect the running server). If these do not help, open a support request and write the service number and what you tried. If after a restart the console shows only the BIOS logo and the server has a graphics card, the operating system may be giving its image from the graphics card; because the console shows the motherboard's built-in video output, this is not a fault.

Powerful performance with Ryzen dedicated servers

In Turkey, with remote management paths.

See the AMD Ryzen dedicated servers

Using the BMC in a technical inspection

When investigating a shutdown or hardware problem of a physical server, BMC data complements the operating-system logs. In the inspection of a physical server, the SistemDC support team can read the hardware event log and sensors, with the access details you supply, by read-only methods. The password you give is held in memory only during that inspection, is not stored and is deleted afterwards; we recommend that you change it after the inspection. The result is delivered as a report that separates what is evidenced from what could not be verified. See the technical inspection report document for the details. This information is not legal advice; the binding text is the agreement.

A remote management checklist when choosing a dedicated server

  • Which BMC does the server have (iLO, iDRAC, ILOM or generic IPMI)?
  • Does the console open in the browser, or is Java required?
  • Can power actions (including hard reset) be done from the panel?
  • Is virtual media (attaching an ISO) supported?
  • Are the hardware event log and sensors visible in the panel?
  • Is BMC access open to the internet, or bridged?

For other points to look at when buying a dedicated server, see the dedicated server checklist.

Related Guides

Frequently Asked Questions

Are IPMI and BMC the same thing?

A BMC (Baseboard Management Controller) is a management controller on the motherboard that works independently of the operating system. IPMI is a standard protocol used to talk to that controller. iLO, iDRAC and ILOM are the vendors' own BMC solutions.

Does the BMC work even if the operating system does not boot?

Yes. Because the BMC works with its own processor and network connection, actions such as power actions, sensor reading and the event log can be performed even when the server is off.

What is the difference between a hard reset and a restart?

A hard reset resets the server without giving the operating system a chance to shut down. On some motherboards a restart from the panel may also reset at hardware level; open files and database operations can therefore be left half-finished.

What is the hardware event log (SEL) for?

It stores hardware events such as power loss, a temperature threshold being crossed and a fan or power supply failure, independently of the operating system. It is one of the most important sources for understanding why a server suddenly stopped.

Is it safe to reach the BMC directly from the internet?

No. BMC interfaces are generally not designed to be left open to the internet. On SistemDC dedicated servers, restricted access to these controllers is bridged through the panel.

Does every dedicated server have a KVM console in the browser?

No, it depends on the hardware. Intel Xeon servers with iLO and iDRAC have a console in the browser; on Oracle / Sun ILOM servers the console is not offered from the panel and a support request is opened.

Is BMC data used in a technical inspection?

In the inspection of a physical server, the hardware event log and sensors can be read with the access the customer supplies. The inspection is read-only and the supplied password is not stored.