Docs
English
Policies and Agreements

Technical Inspection Report: What Is Examined and How to Read It

Last change: Created: ID: SDC-PO-1001

When your server shuts down unexpectedly, slows down or becomes unreachable, the SistemDC support team examines the problem from records rather than guesses and delivers the result as a written technical inspection report. This document explains what is examined, what is not, how to read the report and how data is processed.

The agreement is the binding text: Service and Use Agreement article 17 and the Personal Data and General Privacy Agreement. This page is a summary of them.

When is an inspection carried out?

What is read and what is not

StatusScope
ReadOperating-system event logs (shutdown and boot records, error messages), service status, disk usage, network and resource use, the number and IP addresses of failed login attempts, the status and measurements of the virtual server, and the result of backup jobs.
Not readYour files, databases, e-mails and application data. These are neither read nor copied.
Not changedThe inspection uses read-only methods only. No setting, software, file or data on your server is changed; the server is not restarted or shut down.

Inside virtual servers, information is read only through the guest agent of the virtualization layer and only for reading. If the guest agent is not installed or not running, the information inside the server cannot be read and the report states this clearly (Agreement art. 17.2).

Inspection types

TypeQuestion it answersData examined
Shutdown / restartIf the server stopped suddenly or restarted, what is the cause?Shutdown and boot records, clean-shutdown trace, management actions, events near the time of the shutdown
DiskIs the disk full, read-only or under I/O pressure?Usage and inodes, read-only mounts, I/O pressure, disk health
NetworkIs there packet loss or a connection problem?Interface errors, retransmissions, connection table, failed logins
UnreachableWhy do ping, SSH or RDP not open?Server status, IP configuration, management port listening, firewall, network traffic
High traffic / abuseIs there unexpected traffic or suspected abuse?24-hour network measurement, connection density, connections piling up from a single address
Service / portWhy is a service such as web or database not running?Service status, failed units, listening ports
Backup statusAre backups being taken and when was the last one?Backup job definition, backup results of the last 7 days
Slowness and general healthAre resources sufficient and what is the general state?CPU, memory, disk and network use

What is in the report

A root cause may not be determined. Records sometimes show several possible causes or prove none. In that case the report does not pick a single cause; it writes what is evidenced, what is possible and what is unknown separately.

How the report reaches you

  1. The system reads the records and prepares a draft by rules; the draft is not sent to the customer automatically.
  2. An authorized SistemDC person reviews and approves the draft. After approval the report is given a number and a verification code.
  3. The approved report is delivered as a PDF in reply to your support request or to your registered e-mail address.

The analysis is carried out on SistemDC's own servers by automatic, rule-based software; the collected data is not transferred to a third-party artificial-intelligence service (Agreement art. 17.7).

Physical servers and devices

On physical systems such as dedicated servers, the operating system has to be reached over SSH (Linux, Proxmox, ESXi, Windows OpenSSH), or the hardware through the BMC (iLO, iDRAC; Redfish). The username and password you supply are used for this. The password is held in memory only during that inspection, is not stored and is deleted afterwards (Agreement art. 17.3). We recommend that you change this password after the inspection. On network devices only "show"-type read commands are run; configuration mode is never entered.

Limits of the report

Data and retention

Data processed in the inspection (IP addresses, login attempts, event logs) is processed on the legal grounds of performance of the agreement and legitimate interest. Approved reports are kept for at most 3 years from the date of approval; unapproved drafts and failed inspection records are deleted within 60 days. See the "Technical Inspection and Infrastructure Monitoring" and "Retention Period" sections of the privacy text for details.

Frequently asked questions

Are the files on my server looked at?

No. Your files, databases, e-mails and application data are neither read nor copied. Only operating information such as operating-system event logs and service, disk, network and resource status is examined.

Does the inspection restart my server?

No. The inspection uses read-only methods; nothing is changed on the server and it is neither restarted nor shut down.

Does the report state the root cause with certainty?

Not always. If the records prove the cause, the report states it as evidenced; if they do not, it lists possible causes as "unverified possibility" and does not pick a single one.

Is it safe to give the password of my physical server?

The password is held in memory only during that inspection, is not stored and is deleted. We still recommend that you change the password after the inspection.

How long is a report kept?

Approved reports are kept for at most 3 years from the date of approval; unapproved drafts and failed inspection records are kept for 60 days.

Is artificial intelligence used?

No. The analysis is carried out on SistemDC's own servers by rule-based software; the data is not transferred to a third-party artificial-intelligence service.