If you have ever opened a disk tool, seen "Health: 87%" next to your SSD or NVMe drive and concluded that it is slowing down or running out of life, you are in good company. That percentage says nothing about speed. It is an estimate of how much of the manufacturer's rated write endurance (TBW) has been consumed, and manufacturers set that rating conservatively, so real drives often keep working far beyond it. This guide explains how TBW is defined, what the health figure actually measures, why it has no direct link to performance, and how to estimate real lifespan on your own server.
TBW stands for "Terabytes Written": the total amount of data that can be written to a drive over its life. If a 1 TB NVMe drive is rated at 600 TBW, the manufacturer is saying its reliability criteria will hold up to 600 terabytes of writes. It is a warranty and reliability promise, not an expiry date.
Flash cells wear a little with every erase and write cycle, and endurance depends on the cell type: SLC lasts longest, followed by MLC, TLC and QLC. Vendors derive TBW using the JEDEC endurance methodology (JESD218, with the workload defined in JESD219). The idea is simple: write the drive with a defined workload up to the rated amount, and it must still meet certain criteria afterwards. As summarised in published material about the standard, those criteria look roughly like this:
| Criterion | Client class | Enterprise class |
|---|---|---|
| Functional failure rate allowed at end of rated life | At most 3 percent | At most 3 percent |
| Uncorrectable bit error rate (UBER) | 10 to the power of minus 15 or better | 10 to the power of minus 16 or better |
| Powered-off data retention target | About 1 year (30 °C) | About 3 months (40 °C) |
This table is a commonly quoted summary rather than the standard itself, so check JEDEC documents and your vendor's datasheet for exact values. The point is that TBW describes a worst-case condition: a drive that has been written to its limit must still hold data unpowered for months. Real drives rarely face all those conditions at once.
Tools such as CrystalDiskInfo, Proxmox and vendor utilities display a figure labelled "Health" or "Wearout". On NVMe drives, the source is the Percentage Used field of the SMART/Health log. The NVMe specification defines it as a vendor-specific estimate based on actual usage and the manufacturer's prediction of NAND life. Intel's support documentation makes the same point: a value of 100 means the estimated endurance has been consumed, which does not necessarily indicate a failure, and the value can go above 100 if the drive keeps working past the estimate.
Three consequences follow:
On SATA SSDs the equivalent is a set of vendor-specific SMART attributes (remaining life or a wear-levelling counter). The logic is the same: a normalised value that starts at 100 and falls with wear.
What makes an SSD fast or slow is independent of its wear counter. Two identical models, one at 100 percent and one at 60 percent health, will behave similarly in daily work, while a brand-new drive at 100 percent can look very slow for any of the reasons below:
| Performance factor | What it does |
|---|---|
| Controller and firmware | Queue handling, wear levelling and garbage collection decide most of the speed. |
| Cell type (TLC, QLC) | QLC drives write more slowly and tolerate fewer cycles by design, which is separate from the wear figure. |
| SLC cache | Once the cache fills, write speed drops sharply; this is the usual cause of "my drive got slow" during big copies. |
| Thermal throttling | An NVMe drive with poor cooling reduces its own speed when it gets hot. |
| Fill level and TRIM | A nearly full drive slows down because of write amplification; TRIM and free space help. |
| PCIe lanes and generation | Running at x1 instead of x4, or one generation lower, cuts speed dramatically on the same drive. |
| Queue depth and workload | Small random reads and large sequential writes give completely different numbers. |
To be fair, there is one caveat: on a drive that is extremely worn, error correction and read retries can increase and push up the latency of some reads. That is an edge case for drives very close to the end of their life. For everyday use, "health dropped to 95 percent, so the drive slowed down" is an inference without measurement behind it. When you suspect slowness, check the factors above first and then follow our steps for diagnosing server performance problems.
There are three separate reasons.
First, TBW is a worst-case figure. The vendor sets it so that retention and error-rate requirements still hold at the very end of rated life, which means NAND cells usually have a meaningful margin left at the TBW mark.
Second, the rating is based on a harsh workload. The JEDEC workload is heavy on small random writes, which cause more physical writes inside the drive (write amplification). Many real workloads are lighter, and with sequential-heavy writing the same amount of data wears the cells far less.
Third, commercial caution. Vendors set the number conservatively to manage warranty claims and product tiers.
Independent endurance tests agree. In the Tech Report experiment run between 2013 and 2015, six consumer SSDs were written until they died, and every drive went well beyond its vendor's stated figure; two passed 2 petabytes and the best survivor reached roughly 2.4 petabytes. In another test, a Samsung 850 Pro sold with a 150 TBW rating reached about 9.1 petabytes of writes before reaching end of life. In many tests, in other words, drives lasted several times their rated amount and in some cases many times more.
Read those tests carefully, though:
In short: several times TBW is a common outcome, but it is not a guarantee. Base your plan on backups and redundancy, not on the assumption that a drive will last this long.
Launch your NVMe-backed server
In Istanbul, with KVM virtualization and a 1 Gbps port; see the category pages for current plans.
Browse VDS plansInstead of reading the percentage alone, read these fields together:
There is also an uncomfortable truth: SSDs can fail suddenly because of controller, firmware or power problems, independent of wear, and a drive showing 100 percent health can still go. Monitoring disk health therefore does not replace backups; the two complement each other. For the backup side, see our guide to immutable backups.
On Linux, the smartmontools and nvme-cli packages do the job. The commands below only read; they never write to the drive.
sudo smartctl -a /dev/nvme0
sudo nvme smart-log /dev/nvme0
sudo smartctl -A /dev/sda
The first two are for NVMe drives and the third is for SATA SSDs. In the output, look for percentage_used, available_spare, data_units_written, media_errors and temperature.
On Windows Server you can get the same information with PowerShell:
Get-PhysicalDisk | Get-StorageReliabilityCounter | Select-Object DeviceId, Wear, Temperature, PowerOnHours, ReadErrorsTotal, WriteErrorsTotal
Not every drive reports every field; an empty field means that drive or driver layer does not provide it.
In the NVMe specification, data_units_written counts thousands of 512-byte units, so multiply the value by 512,000 to get bytes. For example, a value of 24,500,000 means roughly 12.5 TB written. The figure may exclude the drive's own internal writes (such as wear levelling), so do not expect the percentage and the TBW to line up exactly.
The simple calculation is remaining TBW divided by daily writes. A drive rated at 600 TBW in a database server that writes 200 GB a day lasts 600 / 0.2 = 3,000 days, around 8 years, and that is using the conservative rating. Vendors also quote DWPD (drive writes per day): multiply TBW by 1,000 and divide by capacity in GB, 365 and the warranty years. For a 1 TB, 600 TBW drive with a 5-year warranty that comes to about 0.33.
| Workload | Write intensity | Drive choice |
|---|---|---|
| Website, application server, file sharing | Low to medium | Standard NVMe is enough |
| Mid-size database, e-commerce | Medium | Standard NVMe in a redundant (RAID) setup |
| Write-heavy database, log collection, queue systems | High | High-endurance enterprise-class drive; monitoring is a must |
| Continuous recording, video render output, backup target | High (sequential) | Sequential writes are gentler, so TBW may last longer; keep generous capacity |
To see your real need, record the daily change in data_units_written for a week first. For drive count and RAID layout see our dedicated server buying checklist, and for NVMe choices on the Ryzen platform see our Ryzen NVMe SSD guide.
The disk you see in a VDS is a virtual disk presented by the virtualization layer, not the physical drive. Running smartctl inside it usually will not show the physical drive's SMART data; physical drive monitoring happens at the provider layer. What you can do inside a virtual server is measure real performance: watch latency with iostat and test read and write speed with fio.
On a dedicated server the drives are yours and the commands above work directly. If you have a question about your disk status, percentage or SMART output, attach the output to your support ticket; tickets are accepted 24/7. You can reach us through the SistemDC contact page.
For outside references, see NVM Express for the NVMe specification fields and the Intel support article for how to read Percentage Used.
Know your hardware on a dedicated server
In Istanbul, with servers you can manage from the browser; see the category page for packages and hardware options.
Browse dedicated serversWhat does TBW mean on an SSD?
TBW (Terabytes Written) is the total amount of data the manufacturer warrants can be written over the drive's life. It is a warranty and reliability figure, not a point at which the drive is expected to fail.
Does 90 percent disk health mean the drive got slower?
No. The health percentage shows how much of the NAND write endurance has been consumed according to the manufacturer's estimate. Speed depends on the controller, cache, temperature, fill level and link width, so the percentage is not a performance measure.
Will an NVMe drive die when Percentage Used reaches 100?
Not necessarily. Per the NVMe specification, 100 means the estimated endurance has been consumed but does not indicate a failure, and the value can exceed 100. At that point you should still review your backups and replacement plan.
Does the warranty end when a drive passes its TBW?
Most vendors warrant a drive for a number of years or its TBW, whichever comes first. Warranty coverage can end at the TBW figure while the drive keeps working. Check your own drive's warranty terms for exact conditions.
How do I check disk health on Linux?
For NVMe drives, 'smartctl -a /dev/nvme0' or 'nvme smart-log /dev/nvme0' prints percentage_used, available_spare, data_units_written and media_errors. For SATA SSDs use 'smartctl -A /dev/sda'.
Should I replace a drive as soon as its health percentage drops?
The percentage alone is not an urgent reason to replace a drive. Read available spare, media errors and critical warning together, and for important data always keep current backups and redundancy such as RAID.
Can an SSD fail before reaching its TBW?
Yes. Controller, firmware, power or component faults can happen regardless of wear. That is why running without backups is never sensible, however long the drive's life looks on paper.
Can I see physical disk health inside a VDS?
The disk you see inside a VDS is a virtual disk, not the physical drive, and it usually does not carry the physical drive's SMART data. Physical drives are monitored at the provider layer; inside the VM you measure performance with tools such as iostat and fio.